Availability: | |
---|---|
Quantity: | |
PCM-L12S100-F74
QUAWINTEC/OEM
8507909000
Shenzhen, China
L/C, T/T, D/P, Western Union, Paypal, Money Gram
white box/polybags/at your request outer package:carton
50PCS
50000/Month
Product name:Protection Circuit Module
Model No:PCM-L12S100-F74
For 5~12S Lithium-ion/Lithium Polymer/LiFePO4 Battery Packs
Product Feature:
1. Suitable for 5-12 section Lithium-ion/Lithium Polymer/LiFePO4 Battery Packs;
2. Connect with special upper computer software, which can display the total voltage, capacity, current, temperature, cycle times and other parameters;
3. cooperate with communication adapter module supports HDQ, I2C, RS232 and RS485 communication protocol;
4. Connect to the special APP via bluetooth;
5. The measurement IC adopts TI BQ series, which can read the parameters such as voltage, capacity, current, temperature, cycle number, etc.
6, with over charge, over discharge, short circuit, over current, temperature protection;
7. The maximum continuous working current is 100A, with the same interface for charging and discharging;
Protection Circuit Module Specifications For 38.4V LiFePO4 Battery Packs | |||
No | Test item (Test at normal temperature 25±2ºC and relative humidity≤90%) | Criterio | |
1 | Communication Interface | RS232/RS485/Bluetooth/I2C | |
2 | Capacity | Designing battery capacity(PCM) | 50Ah |
Max capacity(Battery pack) | 320Ah | ||
Min capacity(Battery pack) | 800mAh | ||
External capacity Indication | LCD,LED | ||
Gas gauge algorithm | Impedance Track | ||
3 | Voltage | Charging voltage | DC: 43.2V CC/CV(3.6V/1cell) |
Cell-balance detection voltage (Charge balance) | 3.6V±0.03V | ||
Cell-balance release voltage | 3.5V±0.025V | ||
Cell-balance detection delay time | 0.96~1.4s | ||
4 | Current | Balance current for single cell | 84±5mA |
Current consumption for single cell | ≤20μA | ||
Normal operating-mode current (Gas Gauge IC) | 600 uA | ||
SLEEP operating-mode current (Gas Gauge IC) | 300 uA | ||
FULL SLEEP operating-mode current (Gas Gauge IC) | 0.1 uA | ||
Maximal continuous charging current | 100A | ||
Maximal continuous discharging current | 100A | ||
5 | Over charge Protection | Over charge detection voltage | 3.900 ± 0.025 V |
Over charge detection delay time | 0.5~2.0S | ||
Over charge release voltage | 3.600 ± 0.050 V | ||
6 | Over discharge protection | Over discharge detection voltage | 2.00 ± 0.080 V |
Over discharge detection delay time | 50~150ms | ||
Over discharge release voltage | 2.70 ± 0.100 V | ||
7 | Over current protectio | Over current detection voltage | 0.2±0.015V |
Over current detection current | 250±50A(can adjust) | ||
Detection delay time | 5~20ms | ||
Release condition | Cut load | ||
8 | Short protectio | Detection condition | Exterior short circuit |
Detection delay time | 200-800us | ||
Release condition | Cut load | ||
9 | Resistance | Protection circuitry (MOSFET) | ≤40mΩ |
10 | Temperatur | Operating Temperature Range | -40~+85ºC |
Storage Temperature Range | -40~+125ºC | ||
Dimension | L240*W120*T15mm | ||
B+:Battery+ | ![]() | ||
B-:Battery- | |||
SDA:I2C data line | |||
SCL:I2C clock line | |||
P+:discharge+ | |||
P-:discharge- | |||
CH+:Charge+ | |||
CH-:Charge- |
Product name:Protection Circuit Module
Model No:PCM-L12S100-F74
For 5~12S Lithium-ion/Lithium Polymer/LiFePO4 Battery Packs
Product Feature:
1. Suitable for 5-12 section Lithium-ion/Lithium Polymer/LiFePO4 Battery Packs;
2. Connect with special upper computer software, which can display the total voltage, capacity, current, temperature, cycle times and other parameters;
3. cooperate with communication adapter module supports HDQ, I2C, RS232 and RS485 communication protocol;
4. Connect to the special APP via bluetooth;
5. The measurement IC adopts TI BQ series, which can read the parameters such as voltage, capacity, current, temperature, cycle number, etc.
6, with over charge, over discharge, short circuit, over current, temperature protection;
7. The maximum continuous working current is 100A, with the same interface for charging and discharging;
Protection Circuit Module Specifications For 38.4V LiFePO4 Battery Packs | |||
No | Test item (Test at normal temperature 25±2ºC and relative humidity≤90%) | Criterio | |
1 | Communication Interface | RS232/RS485/Bluetooth/I2C | |
2 | Capacity | Designing battery capacity(PCM) | 50Ah |
Max capacity(Battery pack) | 320Ah | ||
Min capacity(Battery pack) | 800mAh | ||
External capacity Indication | LCD,LED | ||
Gas gauge algorithm | Impedance Track | ||
3 | Voltage | Charging voltage | DC: 43.2V CC/CV(3.6V/1cell) |
Cell-balance detection voltage (Charge balance) | 3.6V±0.03V | ||
Cell-balance release voltage | 3.5V±0.025V | ||
Cell-balance detection delay time | 0.96~1.4s | ||
4 | Current | Balance current for single cell | 84±5mA |
Current consumption for single cell | ≤20μA | ||
Normal operating-mode current (Gas Gauge IC) | 600 uA | ||
SLEEP operating-mode current (Gas Gauge IC) | 300 uA | ||
FULL SLEEP operating-mode current (Gas Gauge IC) | 0.1 uA | ||
Maximal continuous charging current | 100A | ||
Maximal continuous discharging current | 100A | ||
5 | Over charge Protection | Over charge detection voltage | 3.900 ± 0.025 V |
Over charge detection delay time | 0.5~2.0S | ||
Over charge release voltage | 3.600 ± 0.050 V | ||
6 | Over discharge protection | Over discharge detection voltage | 2.00 ± 0.080 V |
Over discharge detection delay time | 50~150ms | ||
Over discharge release voltage | 2.70 ± 0.100 V | ||
7 | Over current protectio | Over current detection voltage | 0.2±0.015V |
Over current detection current | 250±50A(can adjust) | ||
Detection delay time | 5~20ms | ||
Release condition | Cut load | ||
8 | Short protectio | Detection condition | Exterior short circuit |
Detection delay time | 200-800us | ||
Release condition | Cut load | ||
9 | Resistance | Protection circuitry (MOSFET) | ≤40mΩ |
10 | Temperatur | Operating Temperature Range | -40~+85ºC |
Storage Temperature Range | -40~+125ºC | ||
Dimension | L240*W120*T15mm | ||
B+:Battery+ | ![]() | ||
B-:Battery- | |||
SDA:I2C data line | |||
SCL:I2C clock line | |||
P+:discharge+ | |||
P-:discharge- | |||
CH+:Charge+ | |||
CH-:Charge- |